Request a quote for the analysis of your printed circuit boards.
Choose the tests to be carried out, validate your quote and send us your PCBs for expertise.
Our laboratory will perform the tests and analyzes. We will answer you in 48H with a report following industrial standards.
Our laboratories are in China and North-America.
Test | Testing time | Cost | Select | |
---|---|---|---|---|
PCB Validation test (solderability test) | 2 Days | $ 190 | Select this test Unselect this test | |
![]() Description Solderability test by weeting balance method and meniscograph. Delivery report Solderability test according to IPC standard Machine ASIDA-KH23 - Solder pot |
||||
Microsection PCB | 2 Days | $ 170 | Select this test Unselect this test | |
![]() Description A cross-section will be performed and we will provide a report with measurement and expertise according to IPC standard. Delivery report IC Measurement according to IPC standard Machine KEYENCE VHX-5000- High-performance digital microscope STRUERS LaboPol-20 - Auto-grinding machine |
||||
Microsection PCB Thermal shock (2 microsections) | 3 Days | $ 310 | Select this test Unselect this test | |
![]() Machine ESPEC TSE-12-A - Thermal Shock Tester Delivery report Thermal shock + 2 cross-section (before / After) Description Perform a cross-section, then perform thermal choc (-40 to + 150°C / 10s) and cross-section after thermal choc. |
||||
Microsection PCB Ageing test per 24H (2 microsections) | N/A | $ 310 | Select this test Unselect this test | |
![]() Description Perform one cross-section. Do ageing test (-40 to +150°C / 25 to 98% HR). Perform a second cross-section. Provide report with cross-section before and after ageing test and parameters Machine GWS EL-02KA - Temperature & Humidity Ageing Chamber Delivery report Ageing test + 2 cross-section (before / after) |
||||
Ionic contamination | 2 Days | $ 120 | Select this test Unselect this test | |
![]() Description Ionic contamination measurement based on static method according to IPC-TM-650 (µg/cm2 equivalent NaCl Vs Time) Delivery report Ionic contamination static measurement in µg/cm2 equivalent of NaCl.
Machine METRONELEC CT100- Ionic contamination tester |
||||
Mechanical dimension small | 2 Days | $ 119 | Select this test Unselect this test | |
![]() Description Mechanical dimension checking with CpK report. 32 PCBs with maximum dimension 200x100m. Delivery report Mechanical Measurement + Cpk Machine KEYENCE IM6225 - Image dimension measuring system |
||||
Mechanical dimension large | 2 Days | $ 144 | Select this test Unselect this test | |
![]() Description Mechanical dimension checking. 1 PCB with maximum dimension 400x300m. Delivery report Mechanical Measurement Machine ASIDA 4030 - 2-Dimensional measurement machine |
||||
Tg measurement by DSC | 3 Days | $ 200 | Select this test Unselect this test | |
![]() Description Measure the glass transition temperature (TG) Delivery report Differential Scanning Calorimetry Machine TA Instruments Discovery DSC-25 - DTG Testor (Differential Scanning Calorimetry) |
||||
Surface finish thickness (Au, Ni, Ag, Hasl, Sn) | 2 Days | $ 80 | Select this test Unselect this test | |
![]() Description Perform gold and nickel thickness measurement (10 positions per PCB). Delivery report X-Ray Measurement (10 positions) Machine FISHER XDLM-PCB200 - XRF (Fischer) |
||||
EDX Analysis | 5 Days | $ 227 | Select this test Unselect this test | |
![]() Description Find out what are the chemical components of your PCB on a dedicated area. Delivery report Report (EDX analysis) Machine HITACHI SU8230- EDX (Energy Dispersive X-Ray Spectroscopy) |
PCB Length
PCB Width
Length unit
PCB to be returned after testing
Test | Testing time | Cost | Select | |
---|---|---|---|---|
PCB Validation test (solderability test) | 3 Days | $ 350 | Select this test Unselect this test | |
![]() Description The test includes: • Microsection PCB • Solderability test • Thermal Stress (10 second solder float) • Thermal Stress coupon Evaluation for cracks, voids, de-lamination • Surface Finish thickness by XRF measurement Machine Keyence VHX 7000 Microscope Struers Micro Section System |
||||
Microsection PCB | 3 Days | $ 275 | Select this test Unselect this test | |
![]() Description PCB Micro-section analysis of the copper and “hole” quality is the most thorough of all of the tests as it allows the examiner to look “inside” the PCB at the quality of the construction, the copper plating, the hole formation, the dielectric separation (which also defines the AC impedance), the lamination Process, and the base copper. The IPC has defined 42 different “rejectable” defects that can be seen in one micro section. The test includes: • Extract a part of the PCB to to look “inside” the PCB • In-hole Copper Thickness (Minimum of 6 readings) • Base copper thickness (all layers) • Plated copper thickness • Wicking Length (if excessive) Machine Keyence VHX 7000 Microscope Struers Micro Section System |
||||
Microsection PCB Thermal shock (2 microsections) | 3 Days | $ 500 | Select this test Unselect this test | |
![]() Description Perform one cross-section before and after the thermal shock test (-40 to +150°C / 25 to 98% HR). Provide report with cross-section before and after the thermal shock test. Machine Keyence VHX 7000 Microscope Struers Micro Section System |
||||
Microsection PCB Ageing test per 24H (2 microsections) | 3 Days | $ 500 | Select this test Unselect this test | |
![]() Description Perform one cross-section before and after the ageing test (-40 to +150°C / 25 to 98% HR). Provide report with cross-section before and after ageing test. Machine Keyence VHX 7000 Microscope Struers Micro Section System |
||||
Chamber testing | 3 Days | $ 30/hour (On request) | Select this test Unselect this test | |
![]() Description Thermal shock testing is a cycling of low and high temperature to accelerate failures caused by repeated temperature variations during normal use conditions. In our case, we can perform temperature and humidity variation. Machine T5S5 Environmental Test Chamber: Heat, Cold and Humidity Price for a specific analysis on request 1 to 24 hours : $ 30/hour Minimum value for command : 1h For more, please contact us to: sales@divsys.com |
||||
Ion Chromatography | 4 Days | $ 450 | Select this test Unselect this test | |
![]() Description Separates the different ions to be able to measure the concentration of each of them. Ion Chromatography per IPC TM 650 method 2.3.28. • Ion Chromatography (IC) is employed when the sample fails the IPC maximum acceptability or if the customer has defined a maximum concentration of a specific ION. • For the Ion Chromatograph, there are two types of ions (Anions and Cations). In PCB fabrication, we are usually only concerned with Anions and hence the measurement standard using eqivalent micro grams of chloride. • However, in the no-clean flux of PCBA processing, we also can have Cations. This requires a different measurement system. Both types of ions must be measured and noted for a PCBA. Machine Dionex ICS-2100, Dionex AQUION and ASDV Dionex AQUION ASDV |
||||
Ionic contamination | 3 Days | $ 250 | Select this test Unselect this test | |
![]() Description Cleanliness Testing is used to measure the amount of ionic contamination left on the surface by the PCB process. A cleanliness tester is filled with a solution of 75% AIPA and 25% DI H20 to dissolve the surface contamination. The PCB (Or PCBA) is immersed in the solution. This is a Go / No go test that the PCB or PCBA is clean. The resulting “dirty” solution is measured and converted to a standard using “Equivalent Micro Grams of Sodium Chloride” which is divided by the surface area of the sample to arrive at a ug/in2 or ug/cm2. The IPC acceptance is < 10ug/in2 or < 1.65ug/cm2. Standard cleanliness per IPC TM 650 method 2.3.25. Machine SCS Ionograph BT Series |
||||
Mechanical dimension | 3 Days | $ 150 | Select this test Unselect this test | |
![]() Description Mechanical dimension checking. Machine View Summit System (Non contact CMM). |
||||
Tg measurement by DSC | 3 Days | $ 350 | Select this test Unselect this test | |
![]() Description Measure the glass transition temperature (TG) of the PCB. Machine Ta Instruments Q20 DSC (Differential Scanning Calorimeter). |
||||
Surface finish thickness (Au, Ni, Ag, Hasl, Sn) | 3 Days | $ 150 | Select this test Unselect this test | |
![]() Description Measurement of the surface finish thickness (Au, Ni, Ag, HASL, Sn) by X-Ray Fluorescence on 10 positions Machine Micro Pioneer XRF2000 (X-Ray Fluorescence) |
||||
Bare board electrical test | 3 Days | $ 75/hour (On request) | Select this test Unselect this test | |
![]() Description Automatic test to verify net continuity and the absence of shorts on the board. Machine MicroCraft EMX6151 Flying (Probe Bare Board Tester). Price for a specific analysis on request Hourly price : $ 75/hour Minimum value for command : 1h For more, please contact us to: sales@divsys.com |
||||
PCB Routing / Rework | 3 Days | $ 75/hour (On request) | Select this test Unselect this test | |
![]() Description Rework of PCB like missing holes, incorrect profiles or board size corrections Machine Schmoll MX1-125 Price for a specific analysis on request Hourly price : $ 75/hour Minimum value for command : 1h For more, please contact us to: sales@divsys.com |
PCB Length
PCB Width
Length unit
PCB to be returned after testing
Test | Testing time | Cost | Select | |
---|---|---|---|---|
Microsection PCBA | 3 Days | $ 275 | Select this test Unselect this test | |
![]() Description Extract a part of the PCBA to to look “inside” the PCBA at the quality of the PCB, solder joint or componentsOne microsection that is “ground” to three locations within the solder connectionThe test includes: • Three (3) locations in the solder connection (25%, 50%, 75%) • Thickness of the solder between pin and pad • Size of any voids in the solder connection • Intermetallic thickness Machine Keyence VHX 7000 Microscope Struers Micro Section System | ||||
Chamber testing | 3 Days | $ 30/hour (On request) | Select this test Unselect this test | |
![]() Description Thermal shock testing is a cycling of low and high temperature to accelerate failures caused by repeated temperature variations during normal use conditions. In our case, we can perform temperature and humidity variation. Machine T5S5 Environmental Test Chamber: Heat, Cold and Humidity Price for a specific analysis on request 1 to 24 hours : $ 105/hour Minimum value for command : 1h For more, please contact us to: sales@divsys.com | ||||
Ion Chromatography | 4 Days | $ 450 | Select this test Unselect this test | |
![]() Description Separates the different ions to be able to measure the concentration of each of them. Ion Chromatography per IPC TM 650 method 2.3.28. • Ion Chromatography (IC) is employed when the sample fails the IPC maximum acceptability or if the customer has defined a maximum concentration of a specific ION. • For the Ion Chromatograph, there are two types of ions (Anions and Cations). In PCB fabrication, we are usually only concerned with Anions and hence the measurement standard using eqivalent micro grams of chloride. • However, in the no-clean flux of PCBA processing, we also can have Cations. This requires a different measurement system. Both types of ions must be measured and noted for a PCBA. Machine Dionex ICS-2100, Dionex AQUION and ASDV Dionex AQUION ASDV | ||||
Ionic contamination | 3 Days | $ 250 | Select this test Unselect this test | |
![]() Description Cleanliness Testing is used to measure the amount of ionic contamination left on the surface by the PCB process. A cleanliness tester is filled with a solution of 75% AIPA and 25% DI H20 to dissolve the surface contamination. The PCB (Or PCBA) is immersed in the solution. This is a Go / No go test that the PCB or PCBA is clean. The resulting “dirty” solution is measured and converted to a standard using “Equivalent Micro Grams of Sodium Chloride” which is divided by the surface area of the sample to arrive at a ug/in2 or ug/cm2. The IPC acceptance is < 10ug/in2 or < 1.65ug/cm2. Standard cleanliness per IPC TM 650 method 2.3.25. Machine SCS Ionograph BT Series | ||||
Xray inspection | 3 Days | $ 105/hour (On request) | Select this test Unselect this test | |
![]() Description Check the integrity of a solder connection for the PCBA or the alinement of the layer for the PCBA • When evaluating the integrity of a solder connection, an X-RAY image is invaluable to be able to see the actual connection in a non-destructive fashion. • The X-RAY image can be viewed at various angles to reveal the amount of “attachment between the PCB pads, the component pins and/or the BGA Price for a specific analysis on request 1 to 4 hours : $ 105.00/hour Minimum value for command : 1h For more, please contact us to: sales@divsys.com Machine Keyence VHX 7000 Microscope Struers Micro Section System Nordson Dage Quadra 3 |
PCB Length
PCB Width
Length unit
PCB to be returned after testing